Therefore, if the blower isn't even coming on (1st step), the problem is with the blower, right? This is also something you can do yourself if you transfer the wires one by one or label them. Update: I blew a bunch of debris out from under the heater, not sure if that helps or not though. We had this issue with our Jandy heater. It's a 10 minute job. The shut off to the meter is right on the outside of the unit.D. You cannot paste images directly. For Natural Gas: Minimum 4.0 W.C. to Maximum 10.5 W.C. For Propane: Minimum 4.0 W.C. to Maximum 14 W.C. Will have to verify what I blew out cleaned out underneath good. Section 5. 8,489 satisfied customers. Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools. I ALSO HAVE A LXI 400 2 YEARS OLD, WORKED ONE DAY WHEN FIRST HOOKED UP, SERVICE TECHS SAID METER TOO SMALL, GAS CO. You are using an out of date browser. If backwashing the pool filter doesnt help you, you need to identify which of the reasons mentioned above is causing the issue. Boasting an 84% thermal efficiency rating and a low-NOx design, the JXi is available in both natural and propane gas models. Vocational, Technical or Tra. So I know this is basically to sense air flow into the hot fire box. This is where I learned almost everything I know about this and similar heaters the only good thing that came about from my lightning strike that caused over $5K damage. Stupid question: Doesn't the blower fire up and purge the system BEFORE the igniter is triggered? Low gas supply pressure can also cause a Jandy JXi pool heater ignition fault. Heater comes on, flash plate heats up, gas comes on read more. You must log in or register to reply here. Hello , This is an inactive thread. Looking for a Jandy tech in the Western PA (Pittsburgh) area that might be able to help? Faulty Pilot 7. It is easy to do. The possible causes include- fluctuating filter pump pressure, faulty flame sensor, bad pressure sensor, damaged fan/switch tubing, fan not operating or running slowly, restricted airflow, low gas supply pressure, malfunctioning gas valve, and air in the gas line. Any new postings here are unlikely to be seen or responded to by other members. Paste as plain text instead, blower comes on, ignitor glows then blower goes off and ignitor turns off. I cleaned and then added Corrosion Block. cant hear the gas valve open and it doesnt ignite. This usually indicates a problem in the line. Cycles through 3 times but won't ignite. However, tonight, it had one. You think? Any ideas where is goes of the part number? Can you walk me through the steps? JANDY 200 INSTALLATION AND OPERATION MANUAL Pdf Download PoolSpaForum.com I noticed a 2nd host from the Honeywell air pressure sensor switch that goes to some other box down below behind the fire box. Examine the flue discharge for blockages or restrictions. If it works then that connection is bad. Look at the top or side of the gas valve for the two wires attached to the solenoid terminals. I now keep 2 spares. It is being practiced by thousands of pool owners just like you. Having the same problem. Look at the glass eyeball to see if you see the igniter glowing. UNIT PRE- PURGES 15 SEC, INGNITOR GLOWS 40 SEC, GAS VALVE OPENS, BURNER LIGHTS FOR 4 OR 5 SECONDS THEN IGNITION CONTROL CUTS POWER- NOT SENSING FLAME. However, tonight, it had one. If the gas valve relay makes the loud click and you have no gas odor the only things that can cause that are gas supply or gas control valve. What does ENA mean in a Jandy pool heater? I know you've reported it doesn't light at all but please check again. Disabled Safety Switches 6. We receive monetary benefits in return for showing ADs on this website at no cost to you. After about a week, it stopped working entirely. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. Remove the wires from the terminals of the gas valve. I'm not sure what else to try. If there are no terminals visible, you may need to remove the cover first. If you have an account, sign in now to post with your account. Section 12. When it starts up it only burns for. Jandy Pro Series JXi Pool Heater Troubleshooting Guide. 5 5 comments Best Add a Comment TehSpaz 5 yr. ago Is there a way to force the valve open? Working fine up until yesterday. After doing so, the heater started up just fine for about a week. Maybe mine is LoNox? Did you remove the switch and blow out the sense lines (tubing) and try to drain anything I that may be in the case out? Sorry for the delay, don't know if you still need this but here's what I did: The tech could not find the corroded wire. The diagnostic light does not come on. Jandy JXI "CHECK IGN STEPS"? - Trouble Free Pool I have a jandy LXI 400p. You'll hear a loud metallic click when the relay opens the valve. PoolSpaForum.com There's a round hole that you can put a pencil in the hole to release the latch then swing it out to latch it out about 90 degrees. or Propane?). Hello , This is an inactive thread. One other thing to mention is that I noticed what appear to be dried mouse droppings inside the heater. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: how to repair jandy lrz fault check ignitionPearl Wilson: Assistant: I'll do al. To test for Ohms, double-check that the leads are in the appropriate spot, then grab the switch. Check the gas supply to make sure it matches the gas specified on the heaters rating plate. Getting an "CHECK IGN STEPS" failure code on a Jandy JXi - Reddit In fact, his aim is to help his readers to fix the issues with their heating appliances easily.More about us . I will need to rig up some kind of coat hanger or something to pull out some of that debris under there. I don't know how to further disassemble my heater to get to where the actual blower is mounted. How to repair jandy lrz fault check ignition. For 2 day - YouTube Power cycle the heater to clear the code, try it again the next day- same thing, 65 degrees to 84 totally fine then the error. You will get much more visibility by. I didn't winterize it (didn't know I had to until I just read in the LXi manual today) but I never winterized it before and never had a problem. It's very easy if you have a voltmeter. cleaned out gas jets. It would still be helpful to know/see where the blower itself is. anything may be missing? No visible evidence of damage on ignitor surface (some high temperature discoloring but no white corrosion or evidence of a crack). Defective Igniter 4. If not, the blower motor may be at fault. I vacuumed it out and also put the shop-vac on blower to blow some more out. Click to reveal You can start by cleaning your pool filter. Next step is the blower itself. Make sure you match the model#, the voltages, and the time durations! What if there's a bunch of debris under the heater, could that be interfering with the blower? I've checked the igniter and it seems fine. Do you have an ohm meter? Only after detection does the gas valve open to light up the burners. The wires trace right so it must be. my 16 year old lt just started displaying the AGS error. I can't just pick up my heater cuz it's hooked up to my pipes.. Also, I keep reading there's a fan tubing, what is that, is that for like if I installed my LXi indoors? But what if a critter crawled up in there and died? It is a small rectangular flange with a nipple in the center for the hose. Reset breaker and allow the RS 12 to power up. I saw the spa hit 100 deg and got my suit on. Do you have a variablespeed, or two speed pump on this system? I have a Jandy JXI400 heater. I literally completely disassembled and reassembled the heater to figure out the fix. Fan starts running and cool air starts blowing from the top of the unit, and continues to blow until it shuts down2. PB came out and ( I think) replaced a circuit board. Anyway after I put it back in after checking it, I did tighten the nuts carefully (not so tight as to crack the ignitor base) and still the until did not fire. Your link has been automatically embedded. I tried to fire it up last weekend and it Ask an Expert Home Improvement Questions Pool And Spa Repair Question Summary Answer Summary Gaztech1 here, just signed in, 9H00 am eastern time in CANADA.good morning..I am ready to assist you with your issue. The water is not warm enough or the pump is not operating. When electrical power is added to the hot surface igniter, it transforms into a crystalline element that gets extremely hot. cycles through this 3 times them displays the ags error. I took off the top grate and checked for debris. Locate the hose bib to bleed away air after shutting off the water heater. Hi all!We have a Jandy LXi 250 heater for our salt water pool. The heater has been giving me a bunch of trouble lately and I was hoping someone here may have some insight. Jandy Lxi 250 Heater - Fault Check Ign Control - Pool and Spa Forum New valve should be here in a few days, hopefully at same time as plumber. INSTALLED LARGER METER, NO CHANGE. In this section, we will take a deeper look at the possible reasons why your Jandy pool heater wont ignite and provide you with the simplest solutions. Heater Trouble Zodiac lxi 400N Fault | Trouble Free Pool That includes making sure you were sold the right heater (Gas? https://www.getpoolparts.com/section/1469/jandy-lxi-low-nox-heater-parts Your IP: Section 11. Jandy LXi CHK IGN FAULT - YouTube Pool installation company says "gas meter too small" but I have my doubts as there are 3 X 100,000 BTU/Hr furnaces in the house plus a 6 burner gas range and they have all been "on" in winter months. Each wire is attached to a push-on clip that can be removed from the terminal. By Not solid either. Long-term exposure to high amounts of free chlorine (more than 5 ppm) will induce degradation and premature heat exchanger failure. Our Jandy pro series jxi heater says check flow valve and Our Jandy pro series jxi heater says check flow valve and isnt heating.it was installed 1 month ago read more Poolservice123 Owner Associate Degree 1,028 satisfied customers When I turn pool heater on in shows int he display Fuselink ivereplaced the presssure switch, blower pressure switch, ignition control unit, gas valve and flame sensor. I had this error code recently and it turned out to be a broken ignitor.
Laura Shapira Karet Husband, Do Psa Help Reduce Distracted Driving Incidents, Articles J